Acute Technologies LA2000 Series 

32/64 Channel Logic Analyzers

LA2000 Series PDF

 LA Viewer Software  LA2000 Manual

Models:

TS-LA-2132P

32 Channel, Up to 2MB Total , Logic Analyzer 

TS-LA-2164P

32/64 Channel, Up To 2MB Total, Logic Analyzer

Main Features

  • Enhanced from the LA1000P with the same user interface
    64Channels, 200MHz Sample Rate, Timing & State Analysis
  • Powerful Trigger function :
    16 levels, 4 edges, Width, And/Or, Trigger delay, Pass count...
  • Standard memory size 128k bits/channel; also provides 512k, 2M depth size

General

 

200 MHz High speed timing analysis and 75MHz state analysis, up to 32/64 channels, and 64k-2Mb memory depth per channel. Also with with 16 levels trigger condition, pulse width, delay and more complex trigger settings.  The "Pod" is a case that is 5”1/4 inches in size. Allowing for installation in a PC drive bay case or you can keep it external and place it on your desk for saving your space.

PkLA2000 Potential Use

You can apply the LA2000P to capture many complex signals for circuit debugging. It is also a very good and easy to use learning tool that can assist students to understand a digital timing relationship. The captured waveforms are easy saved for report. You can save it as a Text file for your further analysis or save it to be BMP file to be compared with other waveforms and you can email to your colleagues for shared projects and review. 

A Great Software and Hardware Interface

The LA2000P series has an excellent Windows user-interface. The LA-viewer software can run in Win95/98/ME/2000/NT/XP.  The multi- thread feature allows your tested object to continue to be working with an LA2000P at the same time in one PC. There are three hardware interfaces to connect LA2000P with PC or Notebook: 

Internal-PCI, External-Parallel port and a USB optional adapter. Don’t worry the interface confliction with your system collocation.

Application

By using Acute LA2000P, you can capture unknown system data outputs and reform them with the PG2000 series of pattern generators. The PG2000 will easily be able to read and output data from an LA1000P series logic analyzer immediately. If you combine an LA2000P and PG2000 series, it becomes a powerful auto test and auto certification system. And connecting an LA2000P Trigger-Out port with an oscilloscope Ext-trig port you can capture analog signals as well. 

Specifications

Spec. and Features

LA2132P

LA2164P

Power Power(Internal/External)

PC Power / Adapter(12V)

Static Power Dissipation

3.6W

Max Power Dissipation

11W

Interface Internal

PCI card

External

EPP, Bidirection
(USB optional)

Timing Analysis (Sample Rate)

200 MHz ~ 100 Hz

State Analysis (External Clock)

0 ~ 75MHz

Bandwidth

75 MHz

Channels

32

32/64

Memory Standard Storage Depth (bits/channel)

128k / 64k

Optional Larger Storage Depth

256k/512k; 1M/2M

Trigger Condition

Pattern & Edge

Channels

32

32/64

Pass Count

0 ~ 4095 times

Width (less/more)

10 bits

Delay 28.5 bits
Levels 16
Level to Level relationship Continue/Discontinue
Trigger Logic Type AND/OR
Pre/Post Trigger Yes
Trigger Output Level (BNC port) TTL Level
Trigger acknowledge to BNC delay

< 80ns

Threshold Range

-7.2V ~ +6.8V

Accuracy

± 55mV

Maximum Input Voltage

± 30v

Input Impedance

500KW shunted by 10pF

Temperature Operating

5° C ~ 45° C (41° F ~ 113° F)

Storage

-40° C ~ 75° C (-40° F ~ 167° F)

Data Skew

< 2ns

Software Features Zoom In & Zoom Out

1/2048 ~ 32

Languages

Chininse/English

Wave Height

Adjustiable

Save Wave & Load Wave

Yes

Print Wave

Yes (Range adjustiable)

Project Manager

Yes

Online Help

Yes

Mainframe Volume Length x Width x Height (mm)

197 x 147 x

 

PC Hardware Requirements

1.

PC / INTEL Pentium 100 CPU (or above) compatible.
2. One PCI bus slot.
3. At least 64M bytes RAM.
4. At least 32M bytes available in hard disk.
5. CD-ROM drive (for installation).
6. Display specification, 640x480 VGA (or above), 800x600 or 1024x768 recommended.
7. 101 keyboard, Win95 keyboard recommended.
8. 2 or 3 buttons mouse.
9. Printer EPP mode (/USB port optional for External)
10. Printer (optional).
11. Microsoft Windows 95/98/NT/2000/XP operation system.

 

Ordering information

TS-LA-2132P

32 Channel, Up to 2MB Total , Logic Analyzer 

To Order Online, Search for LA2132 at www.TeamPCTechnology.com 

TS-LA-2164P

32/64 Channel, Up To 2MB Total, Logic Analyzer

To Order Online, Search for LA2164 at www.TeamPCTechnology.com

All LA2000P Series Logic Analyzers Ship With The Following Items:

   LA2132P LA2164P
1. LA2000P mainframe 1 1
2. Signal isolation amplifier box 2 4
3. Signal connector/8-color 1x16 line 2 4
4. Ground line/black 1x2 line with red mark 2 4
5. Probe (Black) 34 68
6. Interface Card (PCI) 1 1
7. Interface Card connect cable(25pins) 1 1
8. Power translate cable 1 1
9. 12VDC 2A Regulator (optional for External) 1 1
10. Printer Round Cable (optional for External) 1 1
11. Installation CD 1 1
12. Manual 1 1
13. Screw 1 1

 

 

Please E-mail Or Call For Pricing, Lead Time And Shipping Fees.
sales@team-solutions.com



Phone: 949.348.7766 • Fax: 949.348.7776
Now Accepting


Copyright Team Solutions 2001
Problems with aTeamSolutions.com, Team-Solutions.com, please email:
webmaster@team-solutions.com

No information here may be reproduced or distributed in any form or by any means without prior permission
from TEAM Marketing, TEAM Solutions Laguna Hills, California, USA.
Please report trouble with the web pages to the webmaster. Thank you.

This site was designed by Duncan Asper 949 458-0477 @ www.whitespace.ws